Overview

Before asking a factory which security product it wants, ask which interrupted operations would affect production or safety. IT handles business information; operational technology (OT) includes technologies that monitor or control physical processes and equipment. The two can be connected. Security changes must account for the equipment’s performance, reliability and safety needs.[1]

1. Put the asset list in operational context

With equipment operators, identify the line, controllers, operator interfaces, connected servers and external maintenance routes. Add each asset’s purpose, owner, location, connections, operating hours and consequences of interruption. CISA and partner agencies describe identifying, classifying and documenting OT assets as a foundation for a defensible architecture.[2]

1. Put the asset list in operational context · Decision table
Customer problemPossible functionAgree first
Connected equipment is unknownAsset and connection inventoryAvailable records, update owner and ways to identify assets without affecting equipment
External maintenance access is hard to traceRequest, approval and session-end recordsAuthorized users and times, emergency route, operator and approver
A fault after a change is hard to diagnoseConfiguration change and recovery historyChange approval, baseline retention, recovery procedure and trial scope

This is a project-selection aid, not an official requirement for every facility.

2. Evaluate security alongside operation

An access log does not solve the customer’s problem if maintenance cannot be performed when needed or a necessary recovery route is blocked. Agree who requests and approves access, how completion is recorded and what differs in an emergency. Plan network changes, device discovery and testing only with the customer’s explicit authorization and safety procedures.

NIST’s OT security guide addresses performance, reliability and safety as well as security.[1] Revision 4 is an initial public draft as of November 7, 2026, so this article primarily references final Revision 3.[3] Foreign guidance does not automatically impose obligations on a particular Korean facility.

3. Hypothetical example: track external maintenance access first

Imagine a parts factory using remote maintenance from two equipment vendors. Its access records are scattered, making it difficult to determine who did what and when after a fault. Instead of changing every machine at once, a supplier could work with the customer on a process for recording access requests, approvals and completion on one line.

Before a trial, agree the existing access method, equipment owner, emergency contact, information to exclude or protect, and how to return to the existing procedure if the work fails. In a customer-approved test environment, check missing records and operator workload; hold wider rollout if problems remain. A one-line trial does not guarantee the safety or incident-free operation of the whole factory.

4. Specify what the customer is buying

The proposal should identify assets and users, functions, integration scope, customer and supplier responsibilities, test period, incident response and maintenance cost. Instead of promising security with one score, document the conditions confirmed, what remains unknown and the next evaluation needed.

Next steps

Contact IRUMJAE with a shareable process overview, the operational problem, staff roles and current access procedure. Do not attach detailed network diagrams or account information to the first inquiry; discuss a secure transfer method before sharing them.

Sources & further reading

Sources checked · 2026-11-07

[1] NIST SP 800-82 Rev. 3

[2] CISA and partners, OT Asset Inventory Guidance